# Vacuum Tube Lifters for Bags and Boxes: Specify the Whole Station

Choose the head for the package, then verify usable lifting stroke, handle reach and support coverage. A complete tube-lifting station includes more than the lifting tube.

Original page: https://www.auto-easy.com/bag-box-vacuum-tube-lifters/
Topic: Selection & Comparisons
Last updated: 2026-11-19

## At a glance

A bag or carton trial needs two results: the head grips through the agreed movement and the filled package arrives intact.

- Load rating. Find the rating for the package surface. A model may list different loads for sealed cartons and porous sacks.

- Samples. Include actual closures, fill levels, pickup faces and difficult batches.

- Damage check. Photograph seams, flaps and walls before and after the trial.

- Station fit. Measure required travel at the load and handle, including the final placement.

- Cycle time. Time pickup, transfer, supported release and return to the next starting position. Include format changes when they form part of the agreed task.

![ETJSQ-V100-30 — Vacuum Tube Lifter.](<https://www.auto-easy.com/api/media/file/tube-head-clean-b7e73dfd55-content-display-ecd3fcd205d75a87.webp>)

ETJSQ-V100-30 — Vacuum Tube Lifter.

## Test the packaging you will actually handle

Provide filled bags and cartons in their normal production condition. Describe seams, perforations, tape, labels, folds and any soft or deformable surface. A material name alone does not show whether a head will seal or whether the package will retain its shape.

|  / Package /  |  / What the selection trial must resolve /  |
| --- | --- |
|  / Paper sack /  |  / Permeability, wrinkles, seam location and usable pickup area. /  |
|  / Woven or perforated bag /  |  / Leakage and the head/source combination on a filled sample. /  |
|  / Plastic bag /  |  / Loose film, folds and deformation under contact. /  |
|  / Carton /  |  / Lid/flap integrity, tape joints, face size and panel stiffness. /  |
|  / Mixed packages /  |  / Which formats share a validated head and which need a different approved setup. /  |

### Separate holding the package from preserving the package

A successful contact does not mean that a sack seam, carton flap or wall can withstand the intended handling sequence. Agree two outcomes for the trial: the prescribed grip is achieved and maintained, and the packaging remains acceptable for its next process. Record leakage, tearing, opening, creasing or permanent deformation separately from a failed pickup.

![Bag-and-box suction head with the perimeter contact material visible. Check the intended contact face on a filled package when selecting the head.](<https://www.auto-easy.com/api/media/file/fill-bag-pad-4f5b10a8d0-content-display-3e74a65d9f33f1da.webp>)

Bag-and-box suction head with the perimeter contact material visible. Check the intended contact face on a filled package when selecting the head.

### Build a sample matrix before the demonstration

Give each sample a reference. Record material, supplier/batch, closure or seam, fill level, filled weight, dimensions, pickup face and its initial condition. Include the normal range of formats and conditions expected in production. Do not quietly substitute a smooth, undamaged demonstration package for a different production package.

Photograph the intended contact face and closure before the agreed trial and record the condition afterwards. List which combinations passed the agreed criteria, which failed and which remain untested. A successful sample is evidence for that tested combination; it is not blanket approval for other packaging, heads or filling conditions. Stop an unsafe trial rather than reproducing a tear or loss of grip.

[Download the blank packaging, workstation and cycle-time workbook](<https://www.auto-easy.com/api/document-files/file/Easytech-Packaging-Workstation-Cycle-Workbook-EN.pdf>). Page 1 records one sample/configuration at a time, including both grip behaviour and packaging condition. It contains no claimed test results.

The [narrow-carton project](<https://www.auto-easy.com/narrow-carton-side-grip-case-study/>) shows why package width matters: cartons 145–190 mm wide needed a side-grip arrangement. Review the contact face and head envelope as well as the 45 kg handling requirement.

## Measure the usable motion at the handle and load

Record the lowest pickup, highest placement, reach from the support, available headroom and operator position. Tube length is not the same as usable lifting stroke. The head, handle and supporting structure take space and affect how the operator reaches the load.

For deep pallets, high stacks or a restricted conveyor, show the most difficult pickup and delivery positions. A cycle filmed at waist height does not mean that the arrangement can reach the bottom of a pallet or the top of the intended stack.

### Check both ends of the task, not only the suspension height

![Side view extracted from an actual Easytech workstation proposal. The drawing shows a 3000 mm arm dimension and a 3200 mm vertical dimension in that proposal. Its depicted load stack and suspended arrangement illustrate why floor coverage and vertical clearance must be reviewed together; these are not universal dimensions, a certified installation or a current model's usable stroke.](<https://www.auto-easy.com/api/media/file/Easytech-Workstation-Side-View-content-display-65dff7e79baafe6d.webp>)

Side view extracted from an actual Easytech workstation proposal. The drawing shows a 3000 mm arm dimension and a 3200 mm vertical dimension in that proposal. Its depicted load stack and suspended arrangement illustrate why floor coverage and vertical clearance must be reviewed together; these are not universal dimensions, a certified installation or a current model's usable stroke.

Use a common floor datum to record the lowest pickup face, highest placement face and lowest overhead obstruction. Then identify the suspension, lifting unit, head, workpiece envelope and operator's handle position at both ends of the movement. The gap between two site heights is a task requirement, not proof that a particular lifting tube can cover it.

A plan view must also show the route between pickup and placement, the load's space through that route and the operator's position. Reach measured to a suspension point does not by itself demonstrate access for the head, workpiece and operator around a machine or pallet. Page 2 of the workbook records these inputs for configuration review.

For a constrained ceiling, compare the [30 kg bag-handling project beneath a 2,600 mm obstruction](<https://www.auto-easy.com/low-headroom-bag-lifting-case-study/>). Its folded-tube arrangement addresses headroom; the requested pickup and placement heights still need to fit the complete station.

## Compare the included components

Component — Quotation detail

- Lifting head

Package formats and approved contact arrangement.

- Handle and lifting unit

Control style, usable movement and operator access.

- Vacuum source

Required supply and location; filtration and connecting hose.

- Support

Jib or rail coverage, mounting, installation and utilities.

- Format changes

Approved heads/couplings and any changed limits.

- Handover

Sample set, configuration record and operating instructions.

## Evaluate the full repeated task

Use representative package weights and pickup heights. Include grip, travel, placement, release and return, with the operator positioned as intended. State your desired throughput as a project requirement; do not use an unrelated demonstration to claim a guaranteed cycles-per-hour value.

Compare price only after the head, source, support and installation responsibilities are aligned. A lifting-unit price and a complete installed-station price are different scopes.

## Screen the package against the correct load column

|  / Model / configuration /  |  / Details /  |
| --- | --- |
|  / [ETJSQ-V140-50 — Vacuum Tube Lifter](<https://www.auto-easy.com/vacuum-tube-lifter-etjsq-v140-50/>) /  |  / Load on sealed surfaces / 50 kg / Load on loose / porous surfaces / 45 kg / Lifting stroke / 1700 / 2500 mm /  |
|  / [ETJSQ-V160-60 — Vacuum Tube Lifter](<https://www.auto-easy.com/vacuum-tube-lifter-etjsq-v160-60/>) /  |  / Load on sealed surfaces / 65 kg / Load on loose / porous surfaces / 60 kg / Lifting stroke / 1700 / 2500 mm /  |
|  / [ETJSV300-250 — Vacuum Tube Lifter](<https://www.auto-easy.com/vacuum-tube-lifter-etjsv300-250/>) /  |  / Load on sealed surfaces / 250 kg / Load on loose / porous surfaces / 200 kg / Lifting stroke / 1650 mm /  |

A hypothetical 50 kg porous sack exceeds ETJSQ-V140-50’s published 45 kg porous-surface figure even though its sealed figure is 50 kg. ETJSQ-V160-60 provides a higher published porous value, but the actual sack and head still need review. Conversely, ETJSV300-250 offers more load but a shorter stated stroke. These comparisons help exclude mismatches before a trial.

## Count the whole repeated cycle

Measure completed handling tasks, not a free-running lifting speed. Define the start and end consistently, use the approved package/head combination and separate initial familiarization from the recorded run. Keep the existing four phases below consecutive so that time is not counted twice.

Phase — Record for each cycle

- Contact

Time from the defined start to the prescribed grip; sample and head identity; failed attempts.

- Transfer

Movement to the destination; pickup/placement positions and restricted approaches.

- Place / release

Supported placement, release and any repositioning needed.

- Return / change

Return to the next defined start; format or tool change where included.

### Keep retries and pauses visible

Use seconds for each measured phase and mark unknown values rather than entering zero. Log a retry in the phase where it occurred; do not add its duration again to the total. Record stoppages outside the cycle separately, with a reason. Retain individual rows so a fast average cannot hide a difficult package or the highest placement position.

For cycles measured from the same start/end definition: mean completed-cycle time = sum of completed-cycle times ÷ number of completed cycles. The corresponding 3600 ÷ mean cycle seconds is a cycle-only hourly equivalent, not guaranteed production output. For observed output during a longer run, use accepted completed transfers divided by the entire elapsed run time, including its recorded pauses. State which measure is reported and its trial conditions.

Page 3 of the workbook provides five blank cycle rows plus pause, retry and result fields. Copy it for a longer run; five rows are a recording layout, not a prescribed statistical sample or acceptance standard. A target takt time remains a requirement until an agreed trial demonstrates the task under the intended conditions.

## Continue your equipment review

[Bag handling](<https://www.auto-easy.com/bag-handling/>) · [Box and carton handling](<https://www.auto-easy.com/box-handling/>) · [Tube lifter configurations](<https://www.auto-easy.com/vacuum-tube-lifters/>)

## Questions for this equipment decision

### Which system elements define a vacuum tube lifter quotation?

The head, lifting tube, vacuum supply, support structure, controls and installation interfaces determine the quotation.

### How should paper, plastic and woven sacks be tested for vacuum lifting?

Test representative paper, plastic and woven sacks separately. Record bag material, sealing, perforations, dust, fill level, weight and the available gripping face. Agree the pickup and release positions and repeat the intended handling cycle with the proposed suction head. Record grip stability and observed cycle time; bag weight alone cannot establish suitability.

### How much headroom does a vacuum tube lifting workstation need?

Measure the lowest overhead obstruction and both pickup and placement heights. The suspension, lifting tube, suction head and load all occupy space. Nominal tube length is not the same as usable vertical travel. Review an arrangement drawing showing the highest and lowest working positions, including any low-headroom configuration.

### What should operators check when a tube lifter raises too slowly or drops unexpectedly?

If movement is unexpected or the load cannot be controlled, stop using the equipment and follow its instructions to make the situation safe. Record the model, workpiece, vacuum indication, supply condition and observed symptom. Filters, hoses, seals, material porosity and the vacuum source need model-specific investigation. Do not bypass protective devices or remove a filter to continue working.

### How should a bag lifting trial be specified before purchase?

Agree a trial list covering the actual bag types, minimum and maximum weights, fill conditions and gripping positions. Include pickup height, placement height, travel route and the intended continuous duty. Record the supplied configuration, observations and agreed acceptance criteria. A trial on one sealed bag does not determine performance for every porous sack.

## Put the operator's hands in the right place

After checking the package and lifting range, place the proposed handle on the workstation side view. Mark where the operator's hands will be on the lowest pallet layer and the highest placement. The handle must be reachable while the suction head is correctly seated—not only while the tube hangs unloaded.

![Different control-handle geometries change where the operator stands and reaches.](<https://www.auto-easy.com/api/media/file/easytech-tube-control-handles-183-content-display-b97c8a7d2a119487.webp>)

Different control-handle geometries change where the operator stands and reaches.

A short one-hand control keeps the hand close to the head. An extended or articulated handle changes that relationship and may make a distant or high contact face accessible. It also occupies space beside the load. Check its sweep past pallet edges, machine guards and adjacent stacks.

![Extended articulated handle drawing, with dimensions in mm: the bend changes hand position relative to the suction head.](<https://www.auto-easy.com/api/media/file/easytech-extended-handle-layout-183-content-display-f6e1c105d2ba65f5.webp>)

Extended articulated handle drawing, with dimensions in mm: the bend changes hand position relative to the suction head.

The illustrated extended handle has a hinged section between the head connection and the handgrip. Use this geometry to discuss access; do not treat it as a universal accessory for every control head. Confirm the complete control unit, connection and intended adjustment for the selected station.

|  / At the trial /  |  / Details /  |
| --- | --- |
|  / Last layer on a pallet /  |  / Look for / Operator can seat the head and use the control without leaning across the load. / If access fails / Review pallet position, handle reach and available tube travel. /  |
|  / Highest stack /  |  / Look for / Control remains reachable during placement and release. / If access fails / Review head height and handle geometry together. /  |
|  / Far corner or machine opening /  |  / Look for / Head reaches the face while the handle clears obstructions. / If access fails / Review the arm path and hand position, not just the arm radius. /  |

Record these positions during the package trial above. If the complete station must move between work areas, use the [mobile-workstation planning guide](<https://www.auto-easy.com/mobile-vacuum-tube-lifter-workstation-planning/>).

## Equipment covered by this guide

- [ETJSQ-V140-50 — Vacuum Tube Lifter](<https://www.auto-easy.com/vacuum-tube-lifter-etjsq-v140-50/>)
- [ETJSQ-V160-60 — Vacuum Tube Lifter](<https://www.auto-easy.com/vacuum-tube-lifter-etjsq-v160-60/>)
- [ETJSV300-250 — Vacuum Tube Lifter](<https://www.auto-easy.com/vacuum-tube-lifter-etjsv300-250/>)